(一)簡介 INTRODUCTION
測壓裝置時用來測試液壓系統中壓力點的壓力,油液通過測壓接頭、軟管總成到耐震壓力表。在常規的液壓系統中,要測試各壓力點的壓力,必須在各壓力點處安裝壓力表及壓力開關,如采用測壓裝置,各測壓點只要安裝測壓接頭,就可測試各壓力點的壓力,省去了壓力表及壓力表開關,從而簡化管路。
測壓裝置分:三表式、 二表式 、 單表式三種 。
CY type pressure testing system is combined with pressure testing
|
|
|
adapter,hose ass-emblly and shock-proof pressure gauge.By installing the pressur testing adapter in your system,you can measure the pressure of the system,but not use of expensive fixed gauges and save time.
The pressure testing system has three types:tri-gauge,gual gauge,single gauge.
測壓裝置各壓力表的量程范圍 THE PRESSURE RANGE AS FOLLO |
三表式 Tri gauge
|
雙表式 Dual gauge
|
單表式 Single gauge
|
0~6MPa、0~25MPa、0~40MPa
|
0~6MPa、0~40MPa
|
0~40MPa
|
測壓裝置配測壓軟管總成 長度為1.5cm(可按用戶要求訂貨)
The hose length of testing system is 1.5cm long(also the length of hose and the pressure rang can be dcided as required)
|
|
(二)型號說明 MODEL CODE
|
|
(三)型號舉例 OPDERING EXAMPLE
需要CY型雙表式測壓裝置時,如最大量程為40MPa,測壓裝置的接口螺紋為M16,用戶測壓接頭為PT-00,則訂貨號為:CY-2-40-M16-H1或CY-3-40-M16-PT-00。
For CY pressure testing system with two guag max,Pressure of 40MPa,connecting thread M16 and adapter connection PT-00,its model will be CY-3-40-M16-PT-00。
|
型 號 Model
|
M1
|
M2(H*)
|
備注remark
|
CY-*-*-M14×1.5-H1
|
M14×1.5
|
M12×1.25
|
|
CY-*-*-M14×1.5-H2
|
M14×1.5
|
M16
|
|
CY-*-*-M14×1.5-H3
|
M14×1.5
|
M14×1.5
|
|
CY-*-*-M14×1.5-H4
|
M14×1.5
|
M16×1.5
|
|
|
型 號 Model
|
M16
|
M2(H*)
|
備注remark
|
CY-*-*-M16-H1
|
M16
|
M12×1.25
|
|
CY-*-*-M16-H2
|
M16
|
M16
|
|
CY-*-*-M16-H3
|
M16
|
M14×1.5
|
|
CY-*-*-M16-H4
|
M16
|
M16×1.5
|
|
|
(四)連接尺寸 MOUNTING SIZE |

|
(五)使用與保養
1.使用該裝置檢測壓力時,必須在測壓系統被測部位安裝測壓接頭,測壓接頭的連接螺紋與測壓軟管的螺紋應相匹配。
2.該測壓裝置可以在液壓系統運行時進行測壓,但應確認被測壓點的壓力在壓力表的量程以內。
3.測壓時,應將測壓裝置平穩放置,測壓點與測壓裝置之間的距離不超過軟管長度的85%。
4.測壓操作時,先將測壓軟管接在測壓裝置相應的壓力表端街頭上,再擰開系統上的測壓接頭的防塵蓋,將測壓軟管的另一端擰在
測壓接頭上,即可進行壓力測試。
5.測壓完畢,必須先擰下測壓接頭端的軟管接頭,旋上防塵蓋后方可擰下測壓裝置端的軟管接頭。
6.測壓完畢,應將測壓裝置上的油污擦干凈,蓋好蓋子并鎖上。
7.測壓裝置在使用和保管時,嚴防碰撞,壓力表使用半年后應送檢。
|